Short, plain definitions of the terms you meet in OTDR traces, event tables, SOR files and test reports, from acquisition range to wavelength. Each one links to a longer explanation where there is one.

A

Acquisition range

How far the OTDR was set to measure, also called the distance range or scan window. It should be longer than the fibre, so the fibre end is on the trace. Stored in the SOR file parameters.

Attenuation

Loss of light along the fibre itself, in dB per km. On a trace it is the slope of the straight parts. Standard single-mode fibre is typically about 0.33 dB/km at 1310 nm and 0.19 dB/km at 1550 nm; in cable, limits of 0.40 and 0.30 dB/km are common.

Averaging

Taking many measurements and averaging them into one trace. More averages, or a longer averaging time, give a smoother trace and a lower noise floor.

B

Backscatter

The small part of the light that the glass scatters back towards the OTDR all along the fibre (Rayleigh scattering). The trace is a plot of backscatter against distance, which is why it slopes down.

Backscatter coefficient

How much light a fibre scatters back for a reference pulse, in dB. The OTDR uses it to calculate reflectance. Stored in the file’s fixed parameters.

Bellcore / Telcordia SR-4731

The standard that defines the SOR file format, so that one file can be read by software from any maker. Version 2 is used by current instruments.

Bidirectional testing

Testing a fibre from both ends and averaging the two results for each event. It removes the error that makes some splices look like gains from one side.

C

Connector

A demountable joint between two fibres. On a trace it is a reflective event: a spike followed by a step down. A good single-mode connector has less than 0.5 dB loss and reflectance below −35 dB.

Cumulative loss

The running total of fibre and event loss from the start of the fibre to each event, calculated from the event table. See cumulative loss vs total loss.

D

Dead zone

The stretch of fibre after a strong reflection where the OTDR cannot see properly, because its receiver is still recovering. The event dead zone is the shortest distance after which a second event can be told apart; the attenuation dead zone is the distance after which its loss can be measured. A launch cable moves the first dead zone off the fibre under test.

Dynamic range

The difference between the backscatter level at the start of the trace and the noise floor, in dB. It sets how much loss, and so how long a fibre, the OTDR can measure.

E

End of fibre

The last event, where the backscatter drops to the noise floor. It may be a connector at the far end, a cut, or a break. Its loss is not defined, but its reflectance is.

Event

Any point where the trace departs from a straight slope: a connector, splice, bend, crack or the end. Events are listed in the event table.

Event code

A short code stored for each event in a SOR file. The first character says if it is non-reflective (0) or reflective (1, or 2 for saturated), the second who placed it (F found by the analysis, A added or M moved by the user, E end of fibre). See event types.

F

Fresnel reflection

The reflection that happens where light meets a change of material, such as glass to air at a connector or a clean break. It causes the spikes on a trace.

Fusion splice

A permanent joint made by melting two fibre ends together. On a trace it is a small non-reflective step, usually 0.02 to 0.1 dB.

G

Gainer

A splice that seems to add light: a step up on the trace and a negative loss in the table. It happens when the fibre after the splice scatters more light back than the fibre before it. Testing from the other end shows a larger loss; the average of the two is the real splice loss.

Ghost

A false reflection on the trace, caused by light bouncing between two strong reflections. It appears at a multiple of the distance to a real reflective event, often beyond the fibre end, and shows no loss.

Group index (IOR)

How much more slowly light travels in the fibre than in a vacuum, usually around 1.467 to 1.468 for single-mode fibre. The OTDR uses it to turn time into distance. See how OTDR distance is calculated.

L

Launch cable

A spool of fibre, often 500 m to 2 km, between the OTDR and the fibre under test. It moves the instrument’s dead zone off the first connector, so that connector can be measured. A receive cable at the far end does the same for the last connector.

Loss budget

The highest total loss a link may have and still pass, worked out from its length, connectors and splices. See pass/fail limits and loss budget.

Loss threshold

The smallest loss the OTDR’s analysis reports as an event. Smaller losses are part of the total, but not in the event table.

M

Macrobend

A bend in the fibre tight enough to leak light, for example in a splice tray or a cable tie. It shows as a non-reflective loss that is larger at 1550 nm than at 1310 nm, which is how you tell it from a bad splice.

Mechanical splice

A joint where two fibre ends are held together in an alignment sleeve with gel, without fusing. It is usually reflective and has more loss than a fusion splice.

N

Noise floor

The level below which the trace is only noise. Beyond the point where the trace reaches it, nothing can be measured.

Non-reflective event

An event with loss but no spike: a fusion splice, a bend or a crack.

O

ORL (optical return loss)

The total light reflected back from the whole link, compared with the light sent in, in dB. Higher is better; values above about 30 dB are typical for good single-mode links.

OTDR

Optical time-domain reflectometer: an instrument that sends light pulses into a fibre and measures the light scattered and reflected back, to show loss and events along its length.

P

Pulse width

The length of each light pulse, in nanoseconds. Short pulses (a few ns) separate events that are close together; long pulses (microseconds) send more light and reach further, at the cost of longer dead zones.

R

Reflectance

The light reflected back by one event compared with the light reaching it, in dB. It is negative; closer to zero is worse. −55 dB is excellent, −35 dB a common limit, −20 dB points to an open or dirty connector.

Reflective event

An event that reflects light back and shows a spike on the trace: a connector, a mechanical splice, or a clean break.

S

Sample spacing

The distance between two points of the trace, the finest step the trace can show. It depends on the pulse width and range chosen.

Section

The length of fibre between two events. Its attenuation is the slope of the trace over that length.

SOR file

Standard OTDR Record, the file an OTDR saves for each measurement, with the extension .sor. See how to open a SOR file and SOR file parameters.

Splice loss

The loss of a splice, in dB. From one end it can be off by the backscatter difference between the two fibres; the average of both directions is the true value.

T

Total loss (end-to-end loss)

The loss of the whole fibre as measured by the OTDR, from the start to the end of the trace. Stored in the SOR file.

Trace

The curve an OTDR draws: backscattered power in dB against distance. Its slope is the fibre’s attenuation; steps and spikes are events.

Two-point loss (A–B)

The loss between two markers placed on the trace, measured from the trace levels at each point. Use the A–B tool in the viewer.

W

Wavelength

The colour of the test light, in nanometres. 1310 and 1550 nm are standard; 1625 or 1650 nm are used to test live fibres without disturbing traffic. Bends show more loss at longer wavelengths.